Aqui faremos sobre o procedimento de fail over e/ou fail back para os seguintes hardwares da EMC: Celerra, VNX Unified e VMAX3 Series.

Conecte via SSH em uma das control stations e use  o comando /nasmcd/getreason para verificar qual é a control station primária e secundária.

[nasadmin@VNXLab ~]$ /nasmcd/getreason
11 – slot_0 secondary control station
10 – slot_1 primary control station
5 – slot_2 contacted
5 – slot_3 contacted
5 – slot_4 contacted

Observe que o na  slot_1 é a primary control station.

Conecte via SSH na secondary control station. (Digite NO quando aparecer a mensagem abaixo).

*** slot_0 secondary control station ***
Would you like to log into the Primary Control Station? (yes or [no]) 

Para alterar a control station:

[nasadmin@VNXLab ~]$ su
Password: (a senha dfault é nasadmin)
[root@VNXXLab nasadmin]# /nasmcd/sbin/cs_standby -takeover
Taking over as Primary Control Station…succeeded

Aguarde de 1 à 3 minutos.

Referências

https://community.emc.com/docs/DOC-45561

Mais Informações

Esperamos ter ajudado da melhor forma possível e estaremos sempre a disposição para mais informações.