Aqui faremos sobre o procedimento de fail over e/ou fail back para os seguintes hardwares da EMC: Celerra, VNX Unified e VMAX3 Series.
Conecte via SSH em uma das control stations e use o comando /nasmcd/getreason para verificar qual é a control station primária e secundária.
[nasadmin@VNXLab ~]$ /nasmcd/getreason
11 – slot_0 secondary control station
10 – slot_1 primary control station
5 – slot_2 contacted
5 – slot_3 contacted
5 – slot_4 contacted
Observe que o na slot_1 é a primary control station.
Conecte via SSH na secondary control station. (Digite NO quando aparecer a mensagem abaixo).
*** slot_0 secondary control station ***
Would you like to log into the Primary Control Station? (yes or [no])
Para alterar a control station:
[nasadmin@VNXLab ~]$ su
Password: (a senha dfault é nasadmin)
[root@VNXXLab nasadmin]# /nasmcd/sbin/cs_standby -takeover
Taking over as Primary Control Station…succeeded
Aguarde de 1 à 3 minutos.